Max Flow: 0.5 to 48 LPM (13 GPM)
Max Temperature: 85°C / 185°F
Max Pressure: 60 PSIG (0.41 MPa)
Materials: Virgin PTFE & PFA
Power: 36kW to 144kW
Voltage: 400
480
Certifications: CE, SEMI S2 & S8
Applications: Semiconductor/Electronics
LED/Flat Panel
Solar
Chemical Processing
Process
The Quantum NXT Recirculation DI Water Heater, Trebor’s latest breakthrough in heating technology, sets a new efficiency and reliability standard. Ideal for high-purity processes requiring continuous hot DIW flows with precise temperature control, Quantum NXT-R conserves energy and water, stabilizing temperatures in variable flow rate applications with buffer tanks and closed-loop pressure vessels. Our heaters’ fast response times and maglev pumps enhance energy efficiency and product quality while reducing resource consumption.
To determine which heater size is needed, calculate the required kilowatt with the following formula:
Required kW = 0.264 * (Flow in GPM) * (Temperature Delta in °C)
Example
Ambient Water Temperature = 25° C
Desired Process Temperature = 70° C
Temperature Delta = 45° C
Required kW = 0.264 * (4 GPM) * (45° C) = 47.5kW
For optimal temperature response and compensation for seasonal changes in ambient water temperature, we recommend adding 20% excess heating capacity.
47.5kW * (1.2) = 57kW
The best option for this application is a 60 kW heater.